Mammography


GE DIAMOND

 

A Design that combines Form, Function & Future

The award-winning Diamond began with a process of analyzing and understanding the key elements involved in breast healthcare.

Its intuitive design started with clinicians and patients and then focused on the human touch that is required in the delicate field of breast imaging. With this approach, the Diamond becomes an extension of the user’s thoughts and actions.

Autopoint helps you get it righ First Time

Diamond brings new intelligence to breast imaging. AutoPoint digitally analyzes breast composition and structure.

PaddleLogic senses which paddle the operator has selected; AutoPoint analyzes only the compressed area of the breast and Diamond collimates automatically to the correct field size for each paddle.

Autopoint selects the correct AEC detectors at the beginning of the exposure. The eight detectors are optimized in size, location and shape.



ParkBack gives you open Workspace for Ergonomic Positioning

The unique ParkBack tubehead moves completely out of the way for a more comfortable positioning posture and avoids stress-related injuries. Better positioning results in better images.

ParkBack also gives completely open workspace for biopsy procedures.

More Breast Tissue with Improved Comfort

ECS (Easy Compression System) is a unique bi-directional compression system which takes advantage of the natural mobility of the breast. It works as a helping hand in all projections to get more posterior breast tissue imaged with improved tissue separation in order to visualize anatomical structures better.

ECS also assists in the positioning of challenging cases such as wheel chair patients, kyphotic patients or patients with small breasts. ECS increases patient comfort and results in more breast tissue being imaged.

The Diamond Tube offers a Sharp Image - time after time

Image quality is everything. The new Diamond x-ray tube ensures this by providing sharper images in breast imaging. The new precision- machined SP-cathode construction gives Gaussian intensity distribution within the focal spot, making the finest details visible in the images, especially with the small focus.

The Integrated Stereotactic System

Delta 32 is a natural extension to the Diamond breast care platform. This integrated digital stereotactic and diagnostic imaging unit is geared to enhance efficiency and patient comfort while the design skillfully combines the clinically correct shape for optimized positioning with sealed construction for easy cleaning.

Delta 32 allows a free choice of projection angle within ±185 ° to minimize the distance from the skin to the lesion. The stereotactic stereotactic angles are freely selectable between ±15 ° by the user to optimize the biopsy accuracy and the volume of view.

The ECS compression system with manual fine tuning informs the user about the applied force and compression thickness, while the motorized movement of the needle guide makes stereotactic examinations more accurate and more convenient

More Confidence with a 3D Image

TACT ®(Tuned Aperture Computed Tomography) technology from GE Healthcare reconstructs a 3-dimensional model of a region of breast from a series of 2 dimensional digital images.

In a TACT ® study, the breast is compressed with a normal spot imaging compression paddle and exposed from different directions using the Diamond ’s semi-automatic stereotactic tubehead movement. This patented method utilizes a reference point in each image to define the geometry, thereby allowing the user to freely select the projection angles.

The clinical benefits of TACT ® are to define if the mammographic finding is caused by a real abnormal lesion or by superposition of normal parenchymal structures, and to detect changes in breast tissue which could otherwise be missed. TACT ® also helps to verify the correct targets for biopsies and to reduce the number of biopsies performed.

TACT ® technology is used in Delta 32 TACT ® and Delta TACT ® for diagnostic digital spot and diagnostic 3D imaging.